ArticleStructuresAnsys MechanicalThermoelectric CoolerThermal-ElectricThermal Stress

Thermal-Structural Analysis of a Thermoelectric Cooler Using Ansys Mechanical

Coupled thermal-electric and structural simulation of a Peltier cooler

SN
Sherlene Ng
Nov 20, 20267 min read
Thermal-Structural Analysis of a Thermoelectric Cooler Using Ansys Mechanical

Introduction

Thermoelectric coolers (TECs), also known as Peltier coolers, are solid-state cooling devices that transfer heat from one surface to another using electrical energy. Unlike conventional refrigeration systems, TECs have no moving mechanical components, making them suitable for applications requiring compact size, precise temperature control and reliable operation.

Common applications include electronic cooling, optical equipment, medical devices and temperature-controlled instrumentation.

Despite their relatively simple construction, designing an effective TEC requires careful consideration of its thermal and electrical behaviour. Increasing the electrical current does not necessarily result in better cooling performance, as the associated Joule heating can reduce the overall cooling capacity. Furthermore, temperature gradients within the assembly can introduce thermal stresses and deformation, potentially affecting the structural integrity of the device.

In this article, we explore how Ansys Mechanical can be used to perform a coupled thermal-electric analysis of a TEC, followed by a structural assessment to evaluate its temperature distribution, cooling performance and thermally induced mechanical response.

Understanding the Thermoelectric Cooling Principle

The operation of a TEC is based on the Peltier effect, a thermoelectric phenomenon in which heat is absorbed or released at the junction of two dissimilar electrical conductors when an electric current passes through them.

A typical TEC consists of multiple pairs of p-type and n-type semiconductor elements sandwiched between two ceramic plates. These semiconductor elements are electrically connected in series and thermally connected in parallel. When a direct current is applied, heat is absorbed at the cold side of the device and released at the hot side. Reversing the current direction reverses the direction of heat transfer.

Schematic of a thermoelectric cooler showing n-type and p-type elements between a cooled surface and a heat-dissipating surface

Three thermoelectric phenomena govern the performance of a TEC:

  • Peltier Effect: Heat is absorbed or released at the junctions of dissimilar materials when an electrical current passes through them.
  • Joule Heating: Electrical resistance generates heat as current flows through the semiconductor elements and electrical conductors.
  • Seebeck Effect: A voltage develops across a temperature difference between two dissimilar materials.

Simulation Workflow

A steady-state Thermal-Electric analysis is first performed to evaluate the temperature distribution and heat-transfer behaviour over time. The resulting temperature field is subsequently transferred to a Static Structural analysis to evaluate thermally induced deformation and stress.

Ansys Workbench project schematic linking a Thermal-Electric system to a Static Structural system

Analysis Assumptions

To simplify the simulation while capturing the primary thermal-electric behaviour of the TEC, the following assumptions are made:

  • Perfect thermal contact: Perfect thermal conduction is assumed between the ceramic plates, heat sink and other components. Thermal contact resistance between interfaces is neglected.
  • Negligible radiation: Heat transfer through thermal radiation is assumed to be negligible and is not included in the model.
  • Constant ambient temperature: The surrounding ambient temperature is assumed to remain constant throughout the simulation.
  • Manual current control: The TEC controller is not modelled. Instead, the electrical current is manually prescribed and varied to investigate its influence on the cooling performance of the device.

Material Definition

The TEC assembly consists of ceramic plates, p-type and n-type semiconductor elements, and copper conductors.

Temperature-dependent material properties are incorporated to account for variations in material behaviour with temperature. The following properties are defined in Ansys Mechanical:

  • Thermal Conductivity: Governs heat conduction through the ceramic plates, semiconductor elements and electrical conductors.
  • Electrical Resistivity: Determines the electrical resistance of the conducting materials and the associated Joule heating.
  • Seebeck Coefficient: Characterises the thermoelectric response of the materials and is required to account for thermoelectric effects.
TEC geometry showing alumina plates, copper alloy conductors, and n-type and p-type elements, with a close-up view

Ansys Mechanical provides an extensive material library containing commonly used TEC materials, including cast iron, graphite and diamond. Additional material data can also be accessed through Ansys Granta, providing a wider selection of materials for engineering applications.

Geometry and Meshing

A hexahedral mesh is generated using the Multizone method, together with local Body Sizing controls to achieve suitable mesh resolution across the different components. The following element sizing is applied:

  • Ceramic plates: 1 mm
  • Copper conductors: 0.5 mm
  • P-type and n-type semiconductors: 0.5 mm

A mesh refinement study can be performed to assess the sensitivity of the predicted temperature, deformation and stress to mesh density.

Boundary Conditions and Load

Thermal Boundary Conditions and Load

Insulation is applied to the external surfaces of the model, except at the heat source and heat sink.

Insulation boundary conditions applied to the external surfaces of the TEC model

A convection boundary condition is applied at the heat sink (hot side) to represent the TEC’s heat dissipation into the environment. The heat sink performance is subsequently reduced after 10 seconds to investigate the effect of impaired heat rejection.

Convection boundary condition on the heat sink side with time-varying convection coefficient

A heat flux is applied uniformly to the heat source (cold side) to represent the TEC’s response under normal operating conditions and an increased thermal load.

Heat flux applied to the heat source surface with its time-varying profile

Electrical Boundary Conditions

In a conventional TEC system, a controller regulates the electrical current to maintain a desired temperature of the heat source (cold side). In this example, the current is prescribed manually to investigate its influence on TEC performance.

Electrical ground and current boundary conditions with the prescribed current ramp over time

Structural Boundary Conditions

For the subsequent Static Structural analysis, fixed supports are applied to the sides of the TEC assembly. The temperature field obtained from the thermal-electric analysis is transferred to the structural model to account for thermal expansion and the resulting stress distribution.

Fixed supports applied to the sides of the TEC assembly in the Static Structural analysis
Close-up view of the fixed support faces on the TEC assembly

Results and Discussion

Thermal Performance and Cooling Behaviour

Under the simulated conditions, the TEC achieves a heat pumping capacity of approximately 26 W.

Heat out of the heat source over time, reaching approximately 26 W at 15 seconds

The temperature and heat flux results at the heat source illustrate the TEC's response to changes in electrical current, thermal loading and heat sink performance throughout the simulation.

Between 0–5 seconds, the heat source temperature decreases slightly as the increasing Peltier cooling effect outweighs the applied thermal load. From 5–10 seconds, the temperature gradually rises as increased Joule heating reduces the overall cooling effectiveness. Between 10–15 seconds, the temperature rises rapidly as reduced heat sink performance limits heat dissipation, causing heat to accumulate within the TEC. Meanwhile, the heat-transfer rate approaches a plateau, indicating that the TEC is nearing its heat pumping limit. These results highlight the importance of effective heat rejection in maintaining TEC cooling performance.

Temperature contour and time history at the heat source
Total heat flux contour and time history at the heat source

Thermo-Structural Response

Following the thermal performance assessment, the temperature distribution from the Thermal-Electric analysis is transferred to a Static Structural analysis to evaluate the mechanical response of the TEC assembly.

The total deformation contour shows the displacement of the TEC assembly due to thermal expansion. Temperature differences across the ceramic plates, semiconductor elements and copper conductors result in non-uniform thermal expansion, causing deformation within the assembly.

Total deformation contour of the TEC assembly due to thermal expansion

The equivalent stress distribution highlights regions experiencing higher thermally induced stresses. Differences in the thermal expansion coefficients of the constituent materials, together with the boundary constraints applied at the sides of the TEC, can generate internal stresses. Identifying these stress concentrations is important for assessing the structural integrity and long-term reliability of the TEC.

Equivalent (von-Mises) stress distribution in the TEC assembly

Conclusion

Thermoelectric cooler performance depends on the interaction between thermoelectric cooling, Joule heating and heat dissipation at the heat sink. Ansys Mechanical enables these coupled thermal-electric effects to be evaluated under varying electrical and thermal operating conditions, providing insight into cooling performance and potential thermal limitations. By linking the thermal-electric analysis to a structural assessment, engineers can also evaluate thermally induced deformation and stress, gaining a more comprehensive understanding of TEC performance and structural reliability.

Found this useful? Share it
CADFEM Expertise

Accelerate your engineering innovation.

Connect with CADFEM experts for advanced simulation, automation, and engineering solutions tailored to your industry.

Contact Us Today